DuBois

Local Reviews
for DuBois, PA


Bill  B.

Bill B.

confirmed with Olivia for 10:30am Emergency / Exit Lights and Sprinkler Inspection

Near Shaffer Rd, DuBois, PA 15801
Bill  B.

Bill B.

Confirmed with Dave for May 14th @10 Annual Ext inspection Portable Extinguishers Inspection

Near Liberty Blvd, DuBois, PA 15801
Jason  M.

Jason M.

Semi-Annual Kitchen Inspection Inoperable Deficiency: System is overflowed Double tank cartridge is due for replacement Duct nozzle is too small over microwave ( needs a 2W ) Plenum nozzle under chain broiler is more than 6" from end of hood System needs manifolded for proper flow coverage ( 2 Cylinders have maxed out for flows ) Duct nozzle for chain broiler is obsolete 8 metals caps are broken or will not stay on Chain broiler, convection oven fryers do not shutdown when tripped Manifold system Remove 245 nozzle beside convection oven and plug to reduce flows( no appliance) Double tank cartridge 1W nozzle 2W nozzle Electrician needed for fryers, chain broiler and convection oven to shutdown 1 stick 3/8 pipe 2 3/8 unions 4 nipples 3/8 plug 8 metal caps

Near E DuBois Ave, DuBois, PA 15801
Jason  M.

Jason M.

Sprinkler Inspection Annual Sprinkler System Inspection

Near Commons Dr, DuBois, PA 15801
Bill  B.

Bill B.

Portable Extinguishers Inspection

Near Beaver Dr, DuBois, PA 15801
Joshua M.

Joshua M.

Portable Extinguishers Inspection.

Near S 8th St, DuBois, PA 15801
Jason  M.

Jason M.

Near S 8th St, DuBois, PA 15801
Bill  B.

Bill B.

Emergency / Exit Lights Inspection

Near Shaffer Rd, DuBois, PA 15801
Jason  M.

Jason M.

Near College Pl, DuBois, PA 15801
Daniel  F.

Daniel F.

Near Shaffer Rd, DuBois, PA 15801
Daniel  F.

Daniel F.

Near S 8th St, DuBois, PA 15801
Jason  M.

Jason M.

Near College Pl, DuBois, PA 15801
Joshua M.

Joshua M.

Portable Extinguishers Inspection

Near S 8th St, DuBois, PA 15801
Dustin  H.

Dustin H.

Sprinkler Inspection

Near Ohio Ave, DuBois, PA 15801
Bill  B.

Bill B.

System is due for a five year internal inspection and gauge replacement. 1 water gauge - repair Confirmed with Manager Becky. store opens at 8am. Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 5 year internal inspection and gauge replacement per NFPA 25. NFPA 25 REQUIREMENTS FOR 5 YEAR TESTING: 13.4.1.2 Alarm valves and their associated strainers, filters, and restricted orifices shall be inspected every 5 years unless tests indicate a greater frequency is necessary 13.4.2.1 Check valves shall be inspecte

Near Commons Dr, DuBois, PA 15801