State College
Local Reviews
for State College, PA
Excellent Service!!!
Tiffany - State College, PA 16801
Bill is one of the best technicians that we work with! He is very informative and is always a pleasure to work with.
Maintenance
Tammy - State College, PA 16801
Grerat
Sam - State College, PA 16801
Easy to work with
Vanessa - State College, PA 16801
Excellent Service!
Taheem - State College, PA 16801
Prompt and professional, doesn't get any better than the best!
Excellent service
Judy - State College, PA 16801
great
Rick - State College, PA 16801
Excellent Service!
Luke - State College, PA 16803
Bill is a good guy. Every time he's been up for anything he has been great.
Great service
Seth - State College, PA 16803
Electrician
Bob - State College, PA 16802
Jason Musselman keeps me in the loop so I can better do my job at PSU.
Great service experience, great prices
Jeremy - State College, PA 16801
Dan was very professional and timely in the servicing of our fire extinguishers. He was on time, friendly, efficient, and made sure we were completely taken care of before leaving. Great experience all around.
store Manager
Bruce - State College, PA 16803
Great service as always, very professional in everything.
Sam - State College, PA 16801
Arize Review
Josh - State College, PA 16803
Great service
Bob - State College, PA 16803
They do a great job
Great service as always, very professional in everything.
Sam - State College, PA 16801
prompt, friendly, professional
Liz - State College, PA 16801
Quick repair
Sam - State College, PA 16801
Great service and prompt repair.
Good service
BILL - State College, PA 16801
Great service as always
Sam - State College, PA 16801
Couldn't be more pleased with the level of service.
Jason M.
Deficiency: FDC cap is missing Control valves are not locked FDC cap Customer needs to find key and have control valves locked open ( lock and chain present with no key )
Jason M.
Annual Sprinkler System Inspection Club House Building Quarterly Sprinkler System Inspection Deficiency: Clubhouse and Buildings 1074,1030,1016 and 3015 do not receive signal at FACP panel ( Audible alarms work but do not send signal to FACP) Alarm Technician needed for all buildings above Deficiency: Clubhouse and Buildings 1088,1074,1030,1016, 3015 do not receive signal at FACP panel ( Audible alarms work but do not send signal to FACP) All above buildings did not receive a trouble signal to FACP Building 1015 tampers are not sending a signal to FACP also 1/4" 3 way valve at pressure gauge at Clubhouse riser needs replaced Alarm Technician needed for all buildings listed above for Tampers and flow switches 1/4" 3 way valve
Jason M.
Quarterly Sprinkler System Inspection
Bill B.
Smoke Alarm Inspections Annual Extinguisher Inspection Annual Sprinkler System Inspection Alarm Systems, Portable Extinguishers, and Sprinkler Inspection
Jason M.
recharge 1- 10lb EXT
Jason M.
Sprinkler Inspection
Bill B.
Sprinkler Repair Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 3 year pressure test of the dry system per NFPA 25. NFPA 25 REQUIREMENTS FOR YEAR TESTING: NFPA 3.4.3.2.6 With the system at normal system pressure, shut off the air source (compressor) for 4 hours. If the low air pressure alarm goes off within this period, the air leaks shall be addressed. Notice of Three Year Dry Sprinkler System Pressure Test Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your esta
Joshua M.
Portable Extinguishers Inspection
Joshua M.
Portable Extinguishers Inspection
Joshua M.
Portable Extinguishers Inspection.
Bill B.
Quarterly Sprinkler System Inspection Sprinkler Inspection
Bill B.
Sprinkler Inspection Quarterly Sprinkler inspection
Jason M.
Deficiency: Recommend replacing 2 1/2" OS&Y valve that is leaking. It is the shutoff before antifreeze loop. Tried to tighten packing. Bolts will not turn due to rust and corrosion. New 2 1/2" OS&Y valve Flange to Flange is 7 5/8 4 bolt 4" center to center on bolt holes with 3" bolts 8 3" new 5/8 bolts 2 gaskets
Jason M.
Sprinkler Service Call Evaluate Water Flow Valve / Fire hose bib in stairwell for quote
Bill B.
Sprinkler Service Call confirmed with Ed- check in at office when you arrive Unit 1814- laundry room sprinkler head leaking
Bill B.
Backflow Inspection
Bill B.
Quarterly Sprinkler System Inspection Sprinkler Inspection
Joshua M.
Portable Extinguishers Inspection
Joshua M.
Portable Extinguishers Inspection
Joshua M.
Annual Extinguisher Inspection.